  1. MG

    2005-2018 Toyota Tacoma HVAC Blower Motor Only Operates on High Speed T-SB-0062-21

    *** This is a continuous problem from the earlier generation Tacoma's that still wasn't fixed with the new Tacoma Here is that Post and TSB. Please see T-SB-0062-21 Applicability: 2005-2018 Toyota Tacoma Introduction: Some 2005 – 2018 model year Tacoma vehicles may exhibit a condition where...
  2. Lewis

    2010 Toyota Corolla Radiator Fans stay on running

    If you run across a 2010 Toyota Corolla and the cooling fans stay running, the air conditioning blower stays on, the keyfob stops working and the headlights stay on all with the key out of the ignition switch, then disconnect the steering angle sensor located on the steering column. Unplugging...
  3. Lewis

    2016-2019 Toyota Tacoma Air Conditioning Blower Motor Stops Working

    How many 2016-2019 Toyota Tacoma Owners out there are experiencing their air conditioning blower motors quite working? Maybe under the same conditions as the previous Tacoma generation documented under T-SB-0149-11. See the Post here...
  4. MG

    2018 Toyota C-HR A/C Not Cooling - Refrigerant Leak

    Some 2018 model year C-HR vehicles may exhibit a condition where the HVAC system intermittently blows warm air from the vents with the A/C on. Follow the Repair Procedure in T-SB-0142-18 bulletin to address this condition. R & R Air Conditioner Tube and Accessory Assembly with updated part...
  5. BGroot

    2016-2017 Toyota Tacoma HVAC Blower Motor SSC J0N

    You can check the status of any SSC on your Toyota here. Please see SSC J0N Here Subject: Special Service Campaign J0N – Remedy Notice 2016 – 2017 Model Year Tacoma HVAC Blower Motor Condition: There is a possibility that the blower motor fan hub in the involved vehicles was produced with...
  6. OishiiJPN

    2018 Toyota C-HR Blower Motor Continuous Operation With Ignition Off

    Some 2018 model year C-HR vehicles may exhibit a condition where the HVAC blower motor will continue to operate when the ignition is turned OFF and the blower motor switch is in any ON position. Other symptoms of this condition can include the A/C not blowing cool air as the A/C amplifier will...
  7. Lewis

    Toyota Main Amp (50 amp blower) blows fuse Open multiple times

    It you run across a Toyota vehicle with a blown (open) main fuse or 50 amp Heater fuse and after installing the new one, the fuse blows again. Then disconnect and check the blower motor as it is most likely shorted. This is due to the vehilce being jumped with the charger leads reversed (jumped...
  8. Lewis

    2016-2017 Toyota Tacoma Blower Motor Noise

    We are seeing quite a few of the 2016-2017 Toyota Tacoma air conditioning blower motors make noise and come apart. The squirrel cage fan will come off of the motor tip. As of now the parts are on backorder with no ETA. If you have this issue, please let us know about it and how long it took for...
  9. MG

    2005-2011 Toyota Tacoma Blower Motor only works on High setting

    *** Please see this new updated Post and TSB for this condition. If you have a 2005-2011 Toyota Tacoma with a concern that the air conditioning blower motor only works on the High speed setting, then you will want to look into replacing the blower motor resister and it's wiring harness. The...